Electronic Fan Controller v2

Electronic Fan Controller v2

74,92 

Gives a warning light when it starts to work, you can adjust it at any time
16-bit microprocessor controlled and equipped with state-of-the-art digital hardware.
Electronic circuit with SMD technology.
Installation is done by a retrofit method.
Temperature control range: -50 to 110°C
Resolution: -9.9 to 99.9, 0.1°C, 1°C for others
Measurement Accuracy: 0.1°C
Control accuracy: 0.1°C
Hysteresis accuracy: 0.1°C
Refresh rate: 0.5 S
High temperature protection: 0-110°C
Input Power: 12V
Measurement inputs: NTC (10K 0.5%) Waterproof sensor
Output: 10A relay
Environmental requirements: -10 to 60°C Humidity 20% to 85%
Power consumption: <= 35mA,
Maximum current: <= 65mA
Size: 48 (U) x 40 (G) x 14 (H) mm
2 year warrant

ncluded:
Electronic Fan Controller
Temperature Sensor with 1 ft pigtail cable
1 meter/3.3 ft cable
Instruction Manuel
Settings
Connect the power supply and the load, you can supply to the controller,
Is displayed as a measured temperature,
Press the SET button, the display flashes the temperature,
Press -&+ to set the desired temperature,
After setting press SET to confirm the return,
The controller automatically performs the relay by setting off!
Long press SET 5 seconds to enter the main menu settings,
Press the + – toggle P0 … P8 long press SET,
10 seconds of no key activity confirmed their return to the controller.
Code        Description                   Setting range         Factory setting

P0            Cooling /Heating                           C/H                              C
P1             Hysteresis setting                         0.5-15                            2
P2            Highest setting upper limit             110                             110
P3            Lowest setting upper limit               -50                             -50
P4            Temperature correction                -7-7℃                             0
P5            Delay start time                        0-10 Minutes                     0
P6            High-temperature alarm               0-110℃                        OFF
Lights, LED status descriptions:
Indicator: Off The relay is switched off, Always indicate the relay is closed.
Display:
LL is the sensor open.
HH is out of range, the thermostat will be forced to close the relay.
— as high-temperature protection.
Note: Relay output interface is a switch when it working, these two ports are connected. If not work, these two ports are not connected.
 